Description of RICOH FT9105 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 SU6/K TECHNICS Service Manual by Rajesh Tanna;
Very clear copy. No pages missing. Big bonus is that it includes supplement. Price is affordable compared to what others ask for.
 TM-1010PN JVC Service Manual by Ken Stevens;
Found the quality of the copy excellent and a very quick service. I would certainly recommend the service.
 RK100/L JVC Service Manual by Menahem Yachad;
Good quality, clear diagrams. Exactly what I needed.
 KRFX7775D KENWOOD Service Manual by H. Zeilstra;
Good product. All the information is invcluded, but due to the complexity of the amplifier, it still is difficult to get it to operation again.
 STR-6055 SONY Service Manual by Teresa RIGAULT;
Very professional seller; very fast, accurate and rielable service.

Text excerpt from page 210 (click to view)
Setting A

1 July 1994

7. If the mean value is improper, select the [4-01] screen and change the flash setting step with
the value change keys (vw) on the process control OFF screen. Changing one step will change approximately 25 volts in the AID reference voltage. select the [4-03] screen again and repeat steps 4 to 7.

8. Press the Process Control ON key on the screen and be sure that all shift steps are 0. Then,

NOTE

⢠When the correct flash setting step is obtained, set the value of the actual VL (measured value) as
the target VL. During the flashing on the [4-03] screen, the actual VL shows the value that should be the target for the VL if the flash output is proper. This makes it easier to obtain the target VL and VD values. (You cannot know the target VD by doing the flashing 10 times on the [4-03] screen. This is because the VD is measured and corrected after flashing 20 times.)

⢠As VD and VL are related, the measured AID reference voltage for the black (or white) area of the
PC-1 chart may change when the flash (or grid) step setting is changed. Therefore, make the following checks and reset the value if the proper flash and grid setting steps have deviated. 1) Repeat steps 3 to 9 of the grid step setting. 2) Repeat steps 1 to 7 of the flash step setting. 3) Set the value of the actual VL (measured value) as the target VL when the correct flash setting step is obtained.

3. Target VL and VD setting The correct flash and grid setting steps have been set in the preceding procedures. In this procedure, read with the [4-01] screen what voltages of the OPC potentials are produced for the black and white patterns on the back of the original scale, and set them as the target VL and VD. After setting the targets, the machine will modify the flash and grid outputs so that the actual VL and VD match the target VL and VD.

1. Place a sheet of A3 (or larger) white paper on the exposure glass, near the original scale.
(This is to prevent change of reflectivity from the white-and-black pattern by a change of original density near the pattern.)

2. Select the [4-01] screen. 3. Press the Process Control OFF key, then press the ON key to reset all shift steps to 0. 4. Press the Start key, and press the Clear/Stop key immediately after the 18th flash. The machine stops after 20 flashes. (This is because the flash output compensation is applied just after flashing 10 times and the grid output compensation is applied just after 20 times.)

5. Read the actual VL (measured value). 6. Set the actual VL value as the target VL using the value change keys (vw) (10 volts per
step). If the actual VL is outside of the target VL adjustable range, set the closest value, and repeat steps 3 to 8 once again after doing step 8.

7. Read the actual VD (measured value). 8. Set the actual VD value as the target VD using the value change keys (vw) (10 volts per
step). If the actual VD is outside of the target VD adjustable range, set the closest value and repeat steps 3 to 8 once again.

5-6

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG-7500 PANASONIC
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

HC-P4752W SAMSUNG
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-KN2000 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

VSX-95 PIONEER
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.155 - Number of Queries: 129 - Query Time: 0.033